Skip to main content
EDGE NEUROTECHNOLOGY FOR PROFESSIONAL REVIEW

The Future of Neurophysiology Happens in Milliseconds. And It Never Leaves Your Clinic.

EpilexBox is the high-precision local-first platform for the analysis and professional review of multichannel EEG signals. Reproducible processing, compatible pattern detection, and real-time artifact isolation—with absolute data sovereignty and zero cloud dependency.

Explore EEG Viewer
Architecture
100% Local-First
Zero raw signal telemetry
Latency
< 4.2 ms
Deterministic edge inference
EEG Formats
EDF / EDF+ / BDF
Universal clinical interoperability
Clinical Framework
Assistive CDSS
Support without replacing clinical judgment
REAL-TIME MULTICHANNEL VISUALIZATION

Dynamic EEG Signal Inspection

Multichannel traces with reproducible filtering and instant marking of compatible segments.

Fp1-F7 / Temporal C3-P3 / Parasagittal Fp2-F8 / Temporal C4-P4 / Parasagittal
Sampling Rate: 500 Hz • Latency < 4.2 ms
CLINICAL-GRADE ARCHITECTURE

Engineered for Neurophysiological Rigor

Every EpilexBox module is engineered to accelerate technical review without compromising strict medical data custody.

PILLAR 01Air-Gapped Ready

Absolute Sovereignty & Local-First

Your patients' bioelectrical recordings are processed and analyzed directly on your local workstation. No EEG traces travel to external servers, guaranteeing immunity to network outages and strict compliance with medical confidentiality.

Zero Raw Signal Egress (0 Bytes Cloud)100% On-Device
PILLAR 02Adaptive Filter

Technical Quality (TQS) & Artifact Isolation

Continuous evaluation of signal-to-noise ratio (SNR) and impedance. Non-destructive isolation of ocular blinks (EOG), muscle myograms (EMG), and 50/60 Hz line interference.

NOISE REJECTION> 118 dB CMRR
TQS SCORE0 - 100% Real-Time
PILLAR 03

Traceability & Evidence

Each detected pattern includes temporo-topographic coordinates, voltage gradient (dV/dt), and a mathematically auditable uncertainty index.

✓ No "Black Box"
PILLAR 04

Complete Session Persistence

Close and reopen the application retaining the exact study state, custom montages, annotations, and review marks without loss of clinical context.

Encrypted Local StorageIndexedDB / SQLite WASM
PILLAR 05

Clinical Reports

One-click export to high-resolution PDF, structured JSON for HIS/EMR interoperability, and CSV for statistical analysis.

PDF • JSON • CSV
CLINICAL WORKFLOW

From Raw Signal to Audited Report

A transparent and reproducible pipeline engineered to augment the diagnostic acuity of neurophysiology teams.

PHASE 01

Multichannel Ingestion & Physical Reading

Instant Local Ingestion

Direct import of EDF, EDF+, BDF, and BrainVision files. Physical channel reading, true microvolts, and automatic scale calibration.

PHASE 02

Reproducible Preprocessing & Quality

IIR Filters / DSP

Technical Quality Score (TQS) assessment, adaptive 50/60 Hz line filtering, and non-destructive isolation of muscle and ocular artifacts.

PHASE 03

Candidate Segment Detection

Verifiable Evidence

Quantitative extraction of EEG features (spectral bands, aEEG) and marking of compatible paroxysmal events with uncertainty metrics.

PHASE 04

Professional Review & Export

Sovereign Clinical Judgment

The specialist validates, discards, or annotates each segment. Structured clinical report generation in PDF with millimeter scale and digital signature.

CLINICAL ACCESS PROGRAM / DEMO

Request Demonstration & Evaluation

Connect with our team. Local-first platform for your epilepsy unit or neurophysiology center.

0 / 3000

🔒 Your data will be treated with strict medical confidentiality and professional privilege.